378
Query Command Library
Parameters
Example
$PASHQ,UDP
$PASHR,UDP,100000.00,100.00,100000.00,100.00*35
Relevant Set
Command
$PASHS,UDP
See Also $PASHS,DYN
UNT: Distance Unit Used on Display Screen
Function This command allows you to know which distance unit is
currently used on the receiver display screen to express the
coordinates of the computed position.
Command Format Syntax
$PASHQ,UNT[*cc]
Response Format Syntax
$PASHR,UNT,s*cc
Parameter Description Range Default
f1
Maximum expected horizontal veloc-
ity, in m/s
0-100 000 100 000
f2
Maximum expected horizontal accel-
eration, in m/s²
0-100 100
f3
Maximum expected vertical velocity,
in m/s
0-100 000 100 000
f4
Maximum expected vertical accelera-
tion, in m/s²
0-100 100
*cc Checksum *00-*FF