After cylcing through all targets and being prompted for reverse readings (optional), you are returned to the target list.
If you highlight a target and click Measure again, you are in effect launching another set of readings. You will be
prompted as shown below:
After completing a set, if you click Measure for measurements, you can accumulate multiple readings which can vary
from target to target, depending on whether you choose to skip certain target readings, do direct only, etc. Each direct
and reverse measurement counts as a reading. You can turn all readings to a target on or off (in the screen, above right)
and by clicking Edit, you can turn any individual reading to a target on or off, as shown below:
When the process is complete and you exit Advanced Occupation, the program adjusts the backsight orientation with