User’s Manual – Leveling Mode
204
Leveling Methods
Survey Pro supports the following leveling methods:
Three Wire
Single Wire
Electronic
Trigonometric
All of the leveling methods can be performed in Manual Mode, where
the readings are read from an instrument and then manually keyed
into the data collector. Electronic and trigonometric methods can be
performed automatically, where the data collector communicates
directly with the instrument and the readings are automatically
transferred to the data collector.
Auto Leveling
If using an instrument where the data will be entered electronically,
activate the existing instrument profile.
1. With Survey Pro in Leveling Mode, open the Job > Settings >
Instrument screen.
2. If an instrument profile does not yet exist, tap the
Create New Instrument button and create a new instrument
profile. (See the Instrument Settings screen in the Reference
Manual for more information on instrument profiles.)