Survey Pro Reference Manual
R-194
ranger finders available on the Job
| Settings | Instrument screen
when in conventional mode. The active instrument will always
return a zenith and slope distance. The active instrument may return
a horizontal angle, which will be treated as an azimuth.
Note: If your laser range finder has a compass, azimuth returned
will be magnetic. Use the Instrument Settings screen to set Magnetic
Declination to apply to the angle.
Store : prompts you for a description, layer, and attribute (depending
on your survey settings) for the new offset point, and stores the point
for the current location.
Occupy Data Points Screen
The Occupy Data Points screen is used to collect measurements to
new points. This screen is used to occupy a point, occupy an offset
reference point, and for feature collection.
Local Coordinates: displays the local coordinates computed from the
current geodetic measurement.
Solution Quality: displays the quality of the current measurement:
the solution type, the number of satellites used, and the horizontal
and vertical precision computed by the receiver. These values are
explained with the GPS Status
screen (Page - R172)
Occupy one Data Point Continuous Feature Collection