Survey Pro Reference Manual
R-238
rule adjustment on the selected traverse.
Adjust elevation
: when selected, the elevations for the traverse
points are also adjusted from the compass rule adjustment.
Adjust Sideshots
: When checked, any side shots that were stored
while occupying the traverse points in the selected traverse will also
be adjusted.
The side shot locations will be recomputed using the original angles
and distances stored in the raw data file along with the adjusted
locations of the occupy and backsight points.
The user cannot explicitly define the side shots that are adjusted.
Instead, they are determined by the information stored in the raw
data file. If no side shots were stored from any of the traverse points,
an error message will be displayed and no adjustment is performed.
If any of the following settings were changed during or after the
traverse was recorded, then side shots cannot be adjusted.
Distance units
Angle units
Earth curvature adjustment
Scale factor
: opens the next screen of the adjustment wizard.